DC-C10A-D air-cooled chiller
Model: DC-C10A-D
Refrigeration capacity: 31KW
Refrigerant: R22, R407C, R410A
Compressor brand:Grain Wheel, Daikin, Danfoss
Warranty period: 1 year
Application scope: Injection molds, laser marking and welding equipment, vacuum coating machines, packaging machinery molds, semiconductor equipment, welding machine electrodes, plasma cutting machines, PCB drilling machine spindle cooling, etc., protect precision equipment and improve production efficiency.
Enquiry
Performance Characteristic
★ The condenser adopts thickened internally threaded copper tubes and corrugated aluminum foil fins, with high heat transfer efficiency and energy saving! The selection of compressors (such as Copeland, Daikin, Danfoss) and refrigeration electronic control components (such as Danfoss, Emerson, Siemens, etc.), with a control accuracy of ± 1 ℃ for ordinary models and ± 0.5 ℃ for precision variable frequency models.
★ Multiple refrigeration circuits can be set up, each circuit can operate independently, suitable for the requirements of variable loads, energy-saving, improving equipment operation safety and stability, and meeting the stringent temperature requirements in various industrial production processes. Room temperature type 7-25 ℃, low-temperature type -60 to -5 ℃.
★ Customizable variable frequency precision chiller, with a temperature control accuracy of ± 0.5 ℃ for chilled water. Accurate temperature control meets the chilled water requirements of precision equipment and saves energy by more than 15-20%.
Application scope
Injection molds, laser marking and welding equipment, vacuum coating machines, packaging machinery molds, semiconductor equipment, welding machine electrodes, plasma cutting machines, PCB drilling machine spindle cooling, etc., protect precision equipment and improve production efficiency.
Technical Parameter
Model |
DC-C3A |
DC-C5A |
DC-C8A-D |
DC-C10A-D |
DC-C12A-D |
DC-C15A-T |
DC-C20A-F |
DC-C25A-F |
DC-C30A-T |
DC-C40A-F |
DC-C50A-F |
Horsepower |
HP |
3 horses |
5 horses |
8 horses |
10 horses |
12 horses |
15 horses |
20 horses |
25 horses |
30 horses |
40 horses |
50 horses |
Refrigeration capacity |
kcal/h |
7181 |
12900 |
20640 |
26660 |
28810 |
38700 |
53320 |
65360 |
79980 |
111800 |
134160 |
KW |
8.35 |
15 |
24 |
31 |
33.5 |
45 |
62 |
76 |
93 |
130 |
156 |
Temperature range ℃ |
7-25℃ |
Power supply |
380V 50HZ 3PH(Special voltage can be customized) |
Refrigerant |
R22(Optional refrigerant R407C, R410A) |
Condenser |
Type |
Air cooled condenser (copper tube wrapped with corrugated aluminum foil heat sink) |
Fan |
Type |
High air volume, low-noise external rotor fan |
Evaporator |
Type |
Water tank coil evaporator (optional stainless steel plate heat exchanger or shell and tube evaporator) |
Water tank capacity L |
50 |
62 |
125 |
125 |
130 |
240 |
300 |
— |
— |
— |
— |
Chilled water pump |
Power KW |
0.37 |
0.37 |
0.75 |
0.75 |
0.75 |
1.5 |
1.5 |
2.2 |
2.2 |
3.7 |
3.7 |
Flow rate of chilled waterm³/h |
1.5-2 |
2-3.5 |
4-5 |
6-7 |
8-9 |
9-10 |
11-15 |
15-18 |
18-21 |
22-28 |
29-35 |
Inlet and outlet diameter of chilled water inch |
1/2' |
1" |
1-1/2” |
1-1/2" |
1-1/2^ |
2" |
2" |
2-1/2" |
2-1/2" |
3” |
3” |
Appearance
Size |
Length D mm |
925 |
1155 |
1255 |
1255 |
1255 |
1800 |
1910 |
1860 |
2100 |
2148 |
2350 |
Width W mm |
575 |
655 |
805 |
805 |
805 |
1050 |
1100 |
1100 |
1250 |
1248 |
1248 |
Height H mm |
1085 |
1082 |
1738 |
1738 |
1738 |
1750 |
1890 |
1930 |
2186 |
2159 |
2350 |
Protection control device |
Delay protection, flow protection, compressor overheating protection, refrigerant high and low pressure protection, overcurrent protection, phase sequence/phase loss protection, overload protection, over temperature protection, etc |
Technical description
1. Selection Description: DC-C10A-D "DC" is the company code of Duoku, "C" represents the chiller, "10" represents the horsepower of 10, "A" represents the air-cooled type, "D" is a dual system with 2 compressors, "T" is a 3 "combined compressor, and" F "is a combination of 4 compressors.
2. The cooling capacity parameters are based on: chilled water inlet and outlet temperatures of 12 ℃/7 ℃, and cooling inlet and outlet air temperatures of 30 ℃/35 ℃.
3. Scope of work: The temperature range of the chilled water is 7 ℃ to 25 ℃, and the temperature difference between the inlet and outlet of the chilled water is 3 ℃ to 8 ℃. The operating environment temperature cannot exceed 40 ℃, and high-temperature models should be selected if the ambient temperature is higher than 40 ℃.
4. Our company reserves the right to change the above parameters or dimensions without prior notice.