97久久国产综合精品久久国产_在线日韩制服中文字幕视频_中文字幕在线播放DH密着_了解最新v天堂在线观看_亚洲av无码片vr一区二区三区_2019年国产精品自拍不卡_成人女人18A级毛片免费_欧美日韩一级在线中文字幕_china3p单男精品自拍_在线综合观看国产

Welcome to Wuxi DOCO Refrigeration web!

TEL:0086-18951583966
CN EN

CONTACT US

Phone : 0086-18951583966

TEL : 0086-510-83785998

FAX : 0086-510-83785966

MAIL : doco@wxdoco.com

WEB : www.docowx.com

ADD : No. 339, Changxin Road, Chang'an Street, Huishan District, Wuxi City

Vacuum Coating

Case  Introduction
DOCO Aired Cooled Chiller applied to vacuum coating industry for customer Hedrich Xiamen
 
 Technical Parameters 
 
Model Item DC-C1A DC-C2A DC-C3A DC-C5A DC-C8A-D DC-C10A-D DC-C12A-D DC-C15A-T DC-C20A-F DC-C25A-D DC-C30A-T
Horsepower HP 1 2 3 5 8 10 12 15 20 25 30
Refrigerating
Capacity
kcal/h 2390 4730 7181 12900 20640 26660 28810 38700 53320 65360 79980
KW 2.78 5.5 8.35 15 24 31 33.5 45 62 76 93
Temperature
Control Range℃
5-25℃
Power Supply 220V 50HZ 1PH 380V 50HZ 3PH
Compressor
Power(kw)
0.83 1.7 2.5 4 3*2 4*2 4.6*2 4*3 4*4 10*2 8*3
Refrigerant R22 ( Environmental Refrigerant R407 and R410 are optional )
Condensor Type Air cooled condenser(corrugated open-window aluminum foil radiating fin with copper tube inside,20% increase
in heat dissipation efficiency)
Fan Type Large-flow and Low-Noise Axial Fan Motor

Evaporator
Type Coil evaporator inside water tank(stainless steel plate heat exchanger or shell tube dry evaporator are optional)
Water tank
volume
20 35 50 62 125 125 130 240 300 350 400
Chilling
water pump
Power KW 0.37 0.37 0.37 0.37 0.75 0.75 0.75 1.5 1.5 2.2 2.2
Chilling water flow  0.6-0.8 0.9-1.3 1.3-1.8 2.6-3.5 4.2-5 5.1-6 6-6.8 7.5-9 10-12 11-13 15-18
Chilling Water Inlet/outlet
Caliber (inch)
1/2" 1/2" 1/2" 1" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2-1/2" 2-1/2"
Dimensions Length mm 605 775 925 1155 1250 1250 1250 1800 1860 1860 2100
Width mm 485 555 575 655 755 755 755 1050 1100 1100 1250
Height mm 876 908 1012 1082 1550 1550 1550 1750 1930 1930 2150
Safety Protection Delay protection, flow protection, compressor overheating protection, refrigerant high and low pressure protection, overcurrent protection, phase sequence / phase deficiency protection, overload protection, overtemperature protection, etc.


 Technical Specifications: 

1. Model number specification: e.g. DC-C10A-D, “DC” indicates Doco company code, “C” indicates chiller, “10” indicates 10 horsepower, “A” indicates air cooled chiller, “D” indicates dual system with two compressors, “T” indicates three compressors, “F” indicates four compressors.
2. *Compressor power: *2indicates two compressors working and two independent refrigerating systems.
3. Refrigerating capacity parameter basis: the temperature of inlet and outlet chilled water is 12℃ / 7℃ and the temperature of inlet and outlet cooling air is 30 ℃ / 35℃.
4. Working ranges: the temperature range of chilling water is from 5℃ to 35℃, the temperature difference between inlet and outlet chilling water is from 3℃ to 8℃, the ambient temperature can not be higher than 40℃, and the high-temperature model should be selected when the ambient temperature is higher than 40℃.
5. We reserve the right to revise the above information without prior notice.
2020/01/07 17:03:05 1167



Copy right ? 2019 Wuxi DOCO Refrigeration Equipments Co., Ltd. All Reserved